Door Systems · Fire Rated Doors, Shutters & Curtains · Since 1993
Fire Rated Doors & Smoke Curtains
120 min
Fire integrity on the Ulti GRP 120 Fire Door (FRR -/120/90sm)
Up to 45 m²
Maximum opening size for our insulated fire rated roller shutter
Since 1993
Supplying, installing and servicing doors across New Zealand
What Is a Fire Rated Door?
A fire rated door is a doorset with a specific fire resistance rating (FRR) that forms part of a fire separation. In a fire it closes automatically and latches. The rating is written as three numbers in minutes, for example -/120/90sm: structural adequacy, integrity and insulation, with “sm” showing smoke control.
The rating belongs to the whole doorset, not just the leaf. The wall, frame, hardware, glazing, size and installation all have to match what was tested or assessed. The rating each opening needs comes from your building’s consented fire design, not a product catalogue. Where an opening has to stay clear day to day, a fire rated curtain or roller shutter can sit out of the way until a fire alarm or heat sensor triggers it.
Fire doors and curtains can also appear on a building’s compliance schedule, so they need regular inspection to support the annual building warrant of fitness (BWoF). Learn more about fire door ratings in our blog.
How Do Fire Doors and Smoke Curtains Work?
Trigger: A fire alarm, heat sensor or self-closer starts the doorset closing. Curtains and shutters wait open until the signal arrives.
Close & latch: The door closes on its own and latches, so pressure from a fire can’t push it open. Propping a fire door open defeats it.
Hold the fire: The leaf, frame and seals hold back flame (integrity) and limit heat on the safe side (insulation) for the rated minutes.
Contain smoke: Where the rating includes “sm”, seals limit smoke leakage, which keeps escape routes usable for longer.
Watch Ulti Fire and Smoke Curtains protect a working site
See how Halls kept day-to-day operations moving with a curtain that waits until it’s needed
Why Choose Ulti for Fire Doors & Smoke Curtains?
Fire door expertise
Practical advice to help you select the right fire rated solution for your building and application.
Nationwide coverage
Support across New Zealand, from initial consultation through to installation and ongoing service.
UltiCare support
Keep your doors performing as they should with ongoing servicing, inspections and preventative maintenance.
Compliance focused
Support for fire doors and smoke curtains that form part of your building’s fire safety and compliance requirements.
Solutions for your site
Options for a range of environments, including cold storage, food processing and other specialised applications.
Long-term support
We’re here beyond installation, helping you look after your doors throughout their working life.
PROJECTS
Real Results From NZ Operations Teams
“Brilliant on every project. Very fast quotes, great installs and good to deal with. Excellent quality safety systems that are innovative and well-priced.”
H&S Advisor
J H Whittaker & Sons
“Ulti is dedicated and, despite difficult site conditions and restricted hours, they did exactly what we wanted – a high-quality job, on time.”
Senior Project Manager
Construction
“10/10… Ulti were very good at dealing with the client and main contractor. They provided detailed and clear pricing information, fast.”
Senior Quantity Surveyor
McMillan & Lockwood














PRODUCT RANGE
The Ulti Group Fire Door & Smoke Curtain Range
Not sure which doorset is right? Jump to how to choose or talk to a specialist →
Mistakes to Avoid When Specifying a Fire Door
Trusting the tag alone
The rating belongs to the doorset. A different wall, frame or opening size can take it outside what was tested.
Ignoring the test direction
Some doorsets are rated one way only. If the direction doesn’t match your fire report, the rating doesn’t apply.
Swapping hardware later
A new closer, lock or trimmed leaf that isn’t covered by the evidence can void the rating. Change it through your supplier.
Assuming hygiene = fire rated
Not every hygiene or hermetic door is fire rated. Check the evidence before you specify it into a separation.
Choosing the wrong door for the application
Every opening has different requirements. Make sure the fire door you choose is suited to the site, application and intended use.
Forgetting the compliance schedule
Fire doors and curtains on a compliance schedule need inspection records to support your annual BWoF.
How to Choose the Right Fire Rated Doorset
Answer these questions and the shortlist writes itself.
What does your fire report specify?
Start with the FRR and smoke control set for the opening. That number, not the product, drives the shortlist.
Which side is the fire risk?
GRP 120 is rated one way only (tested opening out of the furnace). Match the direction to your fire report.
What is the wall built from?
GRP 120 is certified in steel stud with Fyreline GIB, precast concrete and concrete block. Other walls need confirming.
How big is the opening?
Up to 1200 × 2400 mm single or 2400 × 2400 mm double suits GRP 120. Larger openings up to 45 m² may suit a fire rated roller shutter.
Does the opening need to stay clear?
For busy routes, a fire rated curtain or roller shutter waits out of the way until an alarm or heat sensor triggers it.
Is it a washdown or hygiene room?
Food, dairy, pharma and lab rooms suit the Ulti GRP 120 or Ulti GRP 90 Fire Door: moulded GRP leaf with an AISI 304 stainless frame.
Is it a freezer or chiller wall?
Ulti Freezer Fire Doors are built for low-temperature separations. Tell us the temperature, rating and size and we’ll confirm options.
How Much Do Fire Doors Cost in NZ?
What they cost
Price is shaped by the fire rating, smoke control, wall type, opening size, hardware and room conditions like washdown or freezer. Send your fire report and we'll quote.
Install time
Timing depends on the doorset's rating, size and finish, and whether the opening is ready. We confirm lead time with your quote, and our own team installs what you specified.
Inspection & upkeep
NZS 4520 Section 7 sets weekly, monthly, six-monthly and annual checks. Your compliance schedule says which apply. Ulti Care keeps your doors inspection-ready for your BWoF.
A fire door only protects you if it still closes. Ulti Care keeps it inspection-ready.
Preventative maintenance scheduled around your cycle rate, 24/7 nationwide callouts, and parts for all makes and models — so the door that saves you money on day one keeps saving it for the next fifteen years. A typical Ulti Care Protect plan cuts unplanned callouts and adds years of asset life.
RESOURCES
More on Fire Doors & Ratings
OUR NEWS
Featured Articles
Fire Door & Smoke Curtain FAQs
-
A doorset with a fire resistance rating that forms part of a fire separation. In a fire it closes automatically and latches. The rating is written in minutes, such as -/120/90sm: structural adequacy, integrity and insulation, plus “sm” for smoke control.
-
Sometimes. Curtains suit openings that must stay clear, because they stay out of the way until a fire triggers them. Whether one is acceptable for a particular separation depends on your fire design and the product’s test evidence, so confirm it with your fire engineer.
-
It depends on the rating, wall construction, opening size, hardware and room conditions, so there’s no catalogue price. Send your fire report or book a free site visit and we’ll quote against the opening.
-
The GRP 120 Fire Door goes up to 1200 × 2400 mm single leaf or 2400 × 2400 mm double leaf. Our insulated fire rated roller shutter covers openings up to 8 × 8 m.
-
No structural adequacy rating (normal for a door), 120 minutes integrity, 90 minutes insulation and smoke control. On the Ulti GRP 120 Fire Door it applies one way only.
-
No. Its FRR applies one way only, because it was tested opening out of the furnace. Check the door’s direction against your fire report before you specify it.
-
No. Under C/AS2 Table 4.4.1.1, closures in sprinklered buildings have no insulation requirement. In unsprinklered buildings, 30 minutes applies for risk groups SM, CA, WB and VP. Your consented fire report decides.
-
NZS 4520 Section 7 covers inspection, maintenance and reporting, with weekly, monthly, six-monthly and annual checks. The procedures that apply are the ones on your building’s compliance schedule.
-
Some are. Where fire doors or curtains are on the compliance schedule, the owner must show they were inspected and maintained to supply the annual BWoF.
-
The GRP 120 Fire Door is tested to NZS 4520:2010 and AS 1530.4:2014. Our insulated fire rated roller shutter is classified to EN 1634-1. Ask for the evidence for your opening.
-
The consented FRR schedule or fire report, wall construction, opening size and handing, and proposed hardware. If it’s a washdown room or freezer, say so. We’ll come back with candidate doorsets and documentation for your fire engineer.
GET STARTED
Ready to Specify a Fire Rated Opening?
Tell us the opening and the problem. Chances are we’ve already solved something like it.
Got something broken? Call 0800 807 753 — because facilities don’t keep office hours.